Disclaimer
Max flow rate 11L/min.
Compact size and structure, utilizing a brushless servo motor with an integrated driver.
In position control mode, the motor’s absolute position is determined by the number of input pulses.
In speed control mode, the pump speed can be controlled via a 4-20mA or 0–5V analog signal, a pulse frequency signal, or communication commands through the RS485 interface (Modbus RTU protocol).
Equipped with a 17-bit absolute encoder for precise closed-loop motor control, providing real-time speed and fault alarm to support automation control system.
| Parameters | 80 Series |
| Motor type | Brushless servo drive |
| Control circuit board | Yes |
| Max. flow rate(Single Channel) | 11L/min |
| Pumphead model | No(To be ordered separately) |
| Pump speed | 0-600rpm |
| Control mode | RS485,4-20mA,0-5V,0-10kHz(It depends on the product model) |
| Control feature | Position control mode,speed control mode(It depends on the product model) |
| Dimensions(L x W x H) | 198mm*130mm*138mm |
| Installation method | Soleplate mount |
| Power supply | DC24V/260W |
| Operating temperature | 0℃-40℃ |
| Relative humidity | <80% |
Technical Specifications
| Product model | T600-BLC04S-11 | T600-BLA04S-11 | T600-BLV04S-11 | T600-BLF04S-11 |
| Pump Speed | 0-600rpm | |||
| Speed accuracy | ±1rpm | |||
| Speed resolution | 1rpm | |||
| Drive type | Brushless servo drive with 17-bit absolute encoder | |||
| Control mode | Position control mode, speed control mode | Speed control mode | Speed control mode | Position control mode, speed control mode |
| Position control mode | Control the motor's rotation direction and precise angular position via communication commands | N/A | N/A | Control the motor's rotation direction and precise angular position via position pulse signal and direction signal |
| Speed control mode | Control the pump's start/stop, running direction and speed via communication commands | Start/stop control and direction control signals: switch signals (dry contacts) Speed control (0-600rpm): 4-20mA | Start/stop control and direction control signals: switch signals (dry contacts) Speed control (0-600rpm): 0-5V | Start/stop control and direction control signals: switch signals (dry contacts) Speed control (0-600rpm): 0-10kHz (level 5V-24V) |
| Status output | Speed output:10Hz-6kHz for 1rpm-600rpm Fault status output:level signal (low-level by default setting, can be set to high-level) | |||
| Communication control | RS485 interface,Modbus RTU protocol Baud rate:9600bps, 19200bps, 38400bps, 57600bps Parity:none Address:1-127 Stop bit:1bit | N/A | N/A | N/A |
| Power supply | DC24V/260W | |||
| Outline dimension (L*W*H) | 198mm*130mm*138mm | |||
| Working environment | 0℃-40℃, relative humidity<80%,no condensation, altitude<2000m | |||
Compatible Pump Head and Tubing
| Pump Head | Tubings | Max Flow Rate for Reference (mL/min) |
| (1,2) X KZ25-13 | 15#, 24#, 35#, 36# | 6000 (single channel) |
| KZ35-13 | 73#, 82# | 11000 |
| YZ35-13 | 73#, 82# | 11000 |
Dimensions

Flow Curve



Product Enquiry
To purchase or learn more about our products, please contact us and our team will be happy to assist you.
Enquire NowDisclaimer
You are welcome to leave a message for consultation